IBM 86884RX Maintenance Manual - Page 186
Error, symptoms
View all IBM 86884RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
Table 12. LED error codes for the RXE100 port (continued) Error code/symptom FRU/action 9023-180-xxx-xxx (Failed RXE PCIX Backplane Side B LED test) 1. RXE PCI-X backplane (Side B) 2. RXE backplane 9024-180-xxx-xxx (Failed RXE Fans LED test) 1. RXE fans(s) 2. RXE backplane 9025-180-xxx-xxx (Failed RXE backplane LED test) RXE backplane Error symptoms Symptom Suggested action CD-ROM drive problems CD-ROM drive is not recognized. Make sure that: 1. The IDE channels are enabled in the Configuration/Setup Utility program. 2. All cables and jumpers are installed correctly. 3. The correct device driver is installed for the CD-ROM drive. Expansion enclosure problems The SCSI expansion enclosure used to work but does not work now. Make sure that: 1. The cables for all external SCSI options are connected correctly. 2. The last option in each SCSI chain, or the end of the SCSI cable, is terminated correctly. 3. Any external SCSI option is turned on. You must turn on an external SCSI option before turning on the server. For more information, see your SCSI and expansion enclosure documentation. Hard disk drive problems 1. Remove the first drive not recognized, and try the hard disk diagnostic Not all drives are recognized by test again. the hard disk diagnostic test 2. If the remaining drives are recognized, replace the drive you removed with a (Fixed Disk test). new one. System stops responding during 1. Remove the hard disk drive being tested when the server stopped hard disk diagnostic. responding and try the diagnostic again. 2. If the hard disk diagnostic runs successfully, replace the drive you removed with a new one. SCSI drives not recognized 1. Reseat SCSI cable between I/O and T-docking boards. during POST (loose connection) 2. Reseat hard disk drive. CD-ROM drive not recognized 1. Reseat IDE cable and power cable. by SAL/EFI (loose connection) 2. Ensure that SAL/EFI setup has these devices enabled. Not all drives are recognized by 1. Remove first drive that does not show up and rerun diagnostic. If fixed disk diagnostic. remaining drives show up, replace the one that was removed. 2. If remaining drives do not show up, remove successive drives one at a time and rerun diagnostic. System hangs during fixed disk Remove hard drive being tested at the time of the hang and rerun the diagnostic. diagnostic. If successful, replace drive that was removed. 176 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide