IBM 86884RX Maintenance Manual - Page 80

Ethernet, diagnostic, tests, Diagnostic, error, tables

Page 80 highlights

The report generation parameters are as follows: 3. Select CONTINUE after setting report parameters, and press Enter. You can customize how the errors are logged and where the logs are saved using the choices in this menu. You can define the destination for the output, log which tests are conducted, when the test is started, when the test completes, and whether the test will log only errors. Toggle All Tests in Menu Select this choice to display the list of test menus and to select a menu. When you select a menu, the tests for that menu display. Select Toggle all tests to select all tests. Select Toggle all quick tests to select all quick tests. Quick tests are abbreviated versions of the complete test. Run Selected Tests Select this choice to run the tests that you have selected. Toggle Hidden Test Display Select this choice to display all hidden tests. Ethernet diagnostic tests Ethernet diagnostic programs are stored on the Resource CD. To use this CD, complete the following steps: 1. Insert the CD into the DVD/CD-ROM drive, and restart the server. 2. Go to the EFI shell; then, change to the file system on the CD, and navigate to the x450 subdirectory on the CD. 3. Type enet_diag.nsh, and press Enter to run the program from the CD. See the documentation on the Resource CD for more information about Ethernet diagnostic tests and error codes. Diagnostic error code tables For descriptions of the error codes that might appear when you run the AMIDiag program, see "Diagnostic error codes" on page 159. 70 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262

The
report
generation
parameters
are
as
follows:
3.
Select
CONTINUE
after
setting
report
parameters,
and
press
Enter.
You
can
customize
how
the
errors
are
logged
and
where
the
logs
are
saved
using
the
choices
in
this
menu.
You
can
define
the
destination
for
the
output,
log
which
tests
are
conducted,
when
the
test
is
started,
when
the
test
completes,
and
whether
the
test
will
log
only
errors.
Toggle
All
Tests
in
Menu
Select
this
choice
to
display
the
list
of
test
menus
and
to
select
a
menu.
When
you
select
a
menu,
the
tests
for
that
menu
display.
Select
Toggle
all
tests
to
select
all
tests.
Select
Toggle
all
quick
tests
to
select
all
quick
tests.
Quick
tests
are
abbreviated
versions
of
the
complete
test.
Run
Selected
Tests
Select
this
choice
to
run
the
tests
that
you
have
selected.
Toggle
Hidden
Test
Display
Select
this
choice
to
display
all
hidden
tests.
Ethernet
diagnostic
tests
Ethernet
diagnostic
programs
are
stored
on
the
Resource
CD.
To
use
this
CD,
complete
the
following
steps:
1.
Insert
the
CD
into
the
DVD/CD-ROM
drive,
and
restart
the
server.
2.
Go
to
the
EFI
shell;
then,
change
to
the
file
system
on
the
CD,
and
navigate
to
the
x450
subdirectory
on
the
CD.
3.
Type
enet_diag.nsh
,
and
press
Enter
to
run
the
program
from
the
CD.
See
the
documentation
on
the
Resource
CD
for
more
information
about
Ethernet
diagnostic
tests
and
error
codes.
Diagnostic
error
code
tables
For
descriptions
of
the
error
codes
that
might
appear
when
you
run
the
AMIDiag
program,
see
“Diagnostic
error
codes”
on
page
159.
70
IBM
xSeries
450
Type
8688:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide