IBM 86884RX Maintenance Manual - Page 174
DVD-ROM, drive, error, codes
View all IBM 86884RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 174 highlights
IDE DVD-ROM drive test error codes Error Code/Explanation 1900h (Critical/Command Error.) 1901h (DVD Seek Test failed.) 1902h (DVD Read Test failed.) FRU/Action 1. Replace media. 2. Check drive cables and connections. 3. Connect drive to other IDE channel. 4. Drive. 5. I/O board. 1. Replace media. 2. Check drive cables and connections. 3. Connect drive to other IDE channel. 4. Drive. 5. I/O board. 1. Replace media. 2. Check drive cables and connections. 3. Connect drive to other IDE channel. 4. Drive. 5. I/O board. SCSI test error codes Code/Explanation 0500h (SCSI device not ready.) 0502h (SCSI device read error.) 0506h (SCSI disk self test failed.) 0507h (SCSI disk buffer error.) 0508h (SCSI disk random read error.) FRU/Action 1. Confirm that drive is configured. 2. Check drive cables and connections. 3. Drive. 4. I/O board or SCSI add-on controller. 1. Confirm that drive is configured. 2. Check drive cables and connections. 3. Drive. 4. I/O board or SCSI add-on controller. 1. Confirm that drive is configured. 2. Check drive cables and connections. 3. Drive. 4. I/O board or SCSI add-on controller. 1. Confirm that drive is configured. 2. Check drive cables and connections. 3. Drive. 4. I/O board or SCSI add-on controller. 1. Confirm that drive is configured. 2. Check drive cables and connections. 3. Drive. 4. System I/O Board or SCSI add-on controller. 164 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide