IBM 86884RX Maintenance Manual - Page 164
Service, processor, messages
View all IBM 86884RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 164 highlights
Error message/symptom 1810 (Slot x: Unknown PCI error) 1820 (Node 0/PCI slot x: Master Data Parity Error.) 1821 (Node 0/PCI slot x: Detected Parity Error.) 1822 (Node 0/PCI slot x: Signaled System Error.) 1823 (I-node 0/PCI slot x: Received Master Abort.) 1824 (Node 0/PCI slot x: Received Target Abort.) 1825 (Node 0/PCI slot x: Signaled Target Abort.) 1826 (Node 0/PCI slot x: PCI Host Bridge detected an error.) 1962 (Start of [OS] failed.) FRU/action 1. Reconfigure PCI/PCI-X adapters. 2. PCI adapter. 3. PCI-X board. 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board 1. PCI/PCI-X adapter 2. PCI-X board Verify operating system installation/startup media. Service processor messages An example of a typical service processor message is as follows: Log Entry #: 2 Logging Source: ServProc Log Type: E, I, or W Date: 06/17/2003 Time: 6:17:3 Recoverable Error handling example message This message indicates simply that the machine was turned on at the recorded time. The possible service processor error messages are listed in the following table. Note: Try reseating a suspected component or reconnecting a cable before replacing the component. 154 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide