IBM 86884RX Maintenance Manual - Page 74
Batch, Parameters, Cycle, Number, Limit, Passes, Break, Error
View all IBM 86884RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
3. Select Batch Parameters, and press Enter. The following menu is displayed: Cycle Mode Specifies the number of test cycle scripts in the file. In each cycle there can be a different set of test parameters. Cycle Number Specifies whether to test through all of the cycles or just one cycle. This field can be set to All or One. Test Mode The Test mode refers to the overall control, not individual cycles. The test modes are: Mode Continuous Timebound Passbound Description The specified tests run until Esc or Ctrl+Break is pressed. Specify how long the test is to run. Type the hours in the Time Limit Hrs field and the minutes in the Time Limit Min field, and press Enter. The maximum setting for number of hours is 999. The maximum setting for number of minutes is 59. Set the number of passes (up to 65,535) for the selected AMIDiag tests in the Number of Passes field, or press Enter to accept the default (run each selected diagnostic test once). Test Limit Hrs Specifies the time period in hours in case of cycle Timebound test mode. Test Limit Min Specifies the time period in minutes in case of cycle Timebound test mode. Number of Passes Specifies the number of passes of cycles in case of Passbound test mode. Break All on Error This field can be set to YES or NO. If set to YES, the AMIDiag program stops running all tests after it finds an error. 64 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide