Loading a Saved Configuration
View all Intel SE7501HG2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Loading a Saved Configuration To load a previously saved system configuration from a file using the System Setup Utility: 1. From the SSU Main window, choose Config Save/Restore. (Configuration Save/Restore is available only in Expert mode.) 2. Click Restore from File and specify a filename and location. ✏ NOTE You can load only a configuration that had been previously saved with the SSU. To restore the system configuration from a file using the Server Configuration Utility: 1. Boot from the Resource CD into the Server Configuration Wizard. 2. Select the Server Configuration Wizard > Load from Diskette. Click continue. ✏ NOTE You can load only a configuration that had been previously saved with the Server Configuration Wizard. The utility reads the platform type, BIOS revision, and firmware revision from the file and compares that information with the same information retrieved from the server. If the two do not match, an error message is displayed and the load operation aborts. If they do match, the utility saves the configuration data to the server. You will need to reboot your server for the changes to take effect. Configuration Software and Utilities 107