Panasonic AW-UE100 Operating Instructions - Page 75

Acceleration] is set to [Manual]

Page 75 highlights

Camera menu items (continued) Fall Acceleration [1 to 255] Sets the deceleration speed for pan/tilt deceleration operation in 255 steps. (The deceleration speed increases as the number increases) When it is necessary to reduce the speed to the specified speed using manual control of pan/tilt by lever operation etc. through the controller, the deceleration process is performed based on the deceleration speed specified in this setting. This is enabled only when [P/T Acceleration] is [Manual]. • The deceleration and stop processes are carried out right up to the end of the lens mechanism section and in order to prevent a collision with the mechanism, in the actual operation, [Fall Acceleration] may be restricted. Return Return to the previous menu level. „„The relationships between the various setting values during manual operation of pan/tilt when [P/T Acceleration] is set to [Manual] It is possible to specify the responsiveness (maximum speed, acceleration rate, S-curve steps) for operation. • When the specified acceleration speed is small, it is not possible to reach the maximum speed of the product. Acceleration range Range during which the speed reaches the maximum according to that specified by manual operation of pan/tilt Deceleration range Operation speed [Rise S-Curve] 0 to 30 [Fall S-Curve] 0 to 30 The larger that the value of the S-curve is, the greater the speed changes when accelerating or decelerating (represented by the dotted line rather than the solid line), and the operational feel of acceleration and deceleration changes. There is no change in the time taken for accelerating or decelerating with the S-curve setting. Maximum speed reached (Speed specified by manual operation) Acceleration time Time when pan/tilt are manually operated Deceleration time [Rise Acceleration] 1 to 255 The larger the value, the shorter the acceleration time (It takes less time to reach the speed specified with manual pan/tilt operation) [Fall Acceleration] 1 to 255 The larger the value, the shorter the deceleration time (It takes less time to reach the deceleration or stopped status specified with manual pan/tilt operation) 75

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Fall Acceleration [1 to 255]
Sets the deceleration speed for pan/tilt deceleration operation in 255
steps. (The deceleration speed increases as the number increases)
When it is necessary to reduce the speed to the specified speed using
manual control of pan/tilt by lever operation etc. through the controller,
the deceleration process is performed based on the deceleration
speed specified in this setting.
This is enabled only when [P/T Acceleration] is [Manual].
<NOTE>
• The deceleration and stop processes are carried out right up to
the end of the lens mechanism section and in order to prevent
a collision with the mechanism, in the actual operation, [Fall
Acceleration] may be restricted.
Return
Return to the previous menu level.
±
The relationships between the various setting values during manual operation of pan/tilt when [P/T
Acceleration] is set to [Manual]
It is possible to specify the responsiveness (maximum speed, acceleration rate, S-curve steps) for operation.
<NOTE>
• When the specified acceleration speed is small, it is not possible to reach the maximum speed of the product.
Range during which the speed reaches the maximum
according to that specified by manual operation of pan/tilt
Acceleration
range
Acceleration time
Deceleration
range
Deceleration
time
[Rise Acceleration]
1 to 255
The larger the value, the shorter the
acceleration time
(It takes less time to reach the speed
specified with manual pan/tilt operation)
[Fall Acceleration]
1 to 255
The larger the value, the shorter the
deceleration time
(It takes less time to reach the
deceleration or stopped status specified
with manual pan/tilt operation)
Maximum speed reached
(Speed specified by manual
operation)
Time when pan/tilt are manually operated
Operation speed
[Rise S‑Curve]
0 to 30
[Fall S‑Curve]
0 to 30
The larger that the value of the S-curve is, the greater
the speed changes when accelerating or decelerating
(represented by the dotted line rather than the solid line), and
the operational feel of acceleration and deceleration changes.
There is no change in the time taken for accelerating or
decelerating with the S-curve setting.
75
Camera menu items (continued)