H Detail Frequency Uc, Level Depend Threshold Uc
View all Sony PDWHD1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Menu items in the 900s, relating to digital process Item number Item name Settings 953 UP CONVERTER PROCESS (UC) a) Select the source picture to use in converting SD to HD. FIELD: Use field pictures. ADAPTIVE: Frame or field is selected automatically. 954 DETAIL GAIN (UC) a) Adjust the up-converter image enhancer, the sharpness of edge enhancement. 0 to 40H to 7FH 955 LIMITER (UC) a) Adjust the up-converter image enhancer, the maximum detail level added to emphasize the original signal. 0 to 20H to 3FH 956 CRISP THRESHOLD (UC) a) Adjust the up-converter image enhancer, the threshold amplitude at which low amplitude signals are not emphasized. 0 to 8 to FH 957 LEVEL DEPEND THRESHOLD (UC) Adjust the up-converter image enhancer. Set the luminance range for a) edge enhancement. 0 to 8 to FH 958 H DETAIL FREQUENCY (UC) a) Adjust the up converter image enhancer. Set the center frequency and frequency properties for edge enhancement. 3.2MHz: 3.2 MHz ±1.1 MHz 4.5MHz: 4.5 MHz ±1.4 MHz 5.0MHz: 5.0 MHz ±0.7 MHz 4.0MHz: 4.0 MHz ±2.0 MHz 959 H/V RATIO (UC) a) Adjust the up-converter image enhancer. Set the horizontal/vertical ratio for edge enhancement. 0 to 3 to 7 Chapter 7 Menus Setup Menu 145