Compaq DL580R01 Service Guide - Page 105
Adapter/NVRAM ID, Array Configuration Utility.
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
3-36 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Accelerator status: Unrecognized status A status returned from the array accelerator board that ADU does not recognize. Obtain the latest version of ADU. Accelerator status: Valid data found at reset Valid data was found in posted-write memory at reinitialization. Data is flushed to disk. Not an error or data loss condition. No action needs to be taken. Accelerator status: Warranty alert Catastrophic problem with array accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message. Replace the array accelerator board. Adapter/NVRAM ID mismatch EISA nonvolatile RAM has an ID for a different controller from the one physically present in the slot. Run the server setup utility. Array accelerator battery pack X not fully charged Battery is not fully charged. If 75% of the batteries present are fully charged, the array accelerator is fully operational. If more than 75% of the batteries are not fully charged, allow 36 hours to recharge them. Array accelerator battery pack X below reference voltage (recharging) Battery pack on the array accelerator is below the required voltage levels. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. Board in use by expand operation Array accelerator memory is in use Operate the system without the array accelerator by an expand operation. board until the expand operation completes. Board not attached An array controller is configured for Attach array accelerator board to array controller. use with array accelerator board, but one is not attached. Configuration signature is zero ADU detected that nonvolatile RAM contains a configuration signature of zero. Old versions of the server setup utility could cause this. Run the latest version of server setup utility to configure the controller and nonvolatile RAM. Configuration signature mismatch Array accelerator board configured for a different array controller board. Configuration signature on array accelerator board does not match the one stored on the array controller board. To recognize the array accelerator board, run the Array Configuration Utility. Controller communication failure occurred Controller communication failure occurred. ADU was unable to successfully issue commands to the controller in this slot. Controller detected. NVRAM configuration not present EISA nonvolatile RAM does not contain a configuration for this controller. Run the server setup utility to configure the nonvolatile RAM. continued