Compaq DL580R01 Service Guide - Page 113
S.M.A.R.T., Compaq Upgrade Utility. However
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
3-44 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action SCSI port X, Drive ID Y...S.M.A.R.T. predictive failure errors Have been detected in the power Monitor and Performance data. A predictive failure warning for this hard drive generates and indicates a drive failure is imminent. Replace this drive at the earliest opportunity. See "Hot-Plug Hard Drives" in Chapter 2 prior to performing this operation. SOLUTION: Please replace this drive when conditions permit. SCSI port X, Drive ID Y was replaced on a good volume: (failure message) ADU found this drive was replaced, although there was no problem with the volume. No action needs to be taken. Set configuration command issued The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized. Run the server setup utility to reinitialize the array accelerator board. Soft Firmware Upgrade required ADU has determined that your controller is running firmware that has been soft-upgraded by the Compaq Upgrade Utility. However, the firmware running is not present on all drives. This could be caused by the addition of new drives in the system. Run the Compaq Upgrade Utility to place the latest firmware on all drives. continued