Compaq DL580R01 Service Guide - Page 113

S.M.A.R.T., Compaq Upgrade Utility. However

Page 113 highlights

3-44 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action SCSI port X, Drive ID Y...S.M.A.R.T. predictive failure errors Have been detected in the power Monitor and Performance data. A predictive failure warning for this hard drive generates and indicates a drive failure is imminent. Replace this drive at the earliest opportunity. See "Hot-Plug Hard Drives" in Chapter 2 prior to performing this operation. SOLUTION: Please replace this drive when conditions permit. SCSI port X, Drive ID Y was replaced on a good volume: (failure message) ADU found this drive was replaced, although there was no problem with the volume. No action needs to be taken. Set configuration command issued The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized. Run the server setup utility to reinitialize the array accelerator board. Soft Firmware Upgrade required ADU has determined that your controller is running firmware that has been soft-upgraded by the Compaq Upgrade Utility. However, the firmware running is not present on all drives. This could be caused by the addition of new drives in the system. Run the Compaq Upgrade Utility to place the latest firmware on all drives. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193

3-44
Compaq ProLiant DL580 Server Maintenance and Service Guide
Table 3-18
Array Diagnostic Utility (ADU) Error Messages
continued
Message
Description
Recommended Action
SCSI port
X
, Drive
ID
Y
S.M.A.R.T.
predictive failure
errors
Have been detected
in the power Monitor
and Performance
data.
SOLUTION: Please
replace this drive
when conditions
permit.
A predictive failure warning for this
hard drive generates and indicates
a drive failure is imminent.
Replace this drive at the earliest opportunity.
See
Hot-Plug Hard Drives
in Chapter 2 prior to
performing this operation.
SCSI port
X
, Drive
ID
Y
was replaced on
a good volume:
(failure message)
ADU found this drive was replaced,
although there was no problem
with the volume.
No action needs to be taken.
Set configuration
command issued
The configuration of the array
controller has been updated. The
array accelerator board may remain
disabled until it is reinitialized.
Run the server setup utility to reinitialize the
array accelerator board.
Soft Firmware
Upgrade required
ADU has determined that your
controller is running firmware that
has been soft-upgraded by the
Compaq Upgrade Utility. However,
the firmware running is not present
on all drives. This could be caused
by the addition of new drives in the
system.
Run the Compaq Upgrade Utility to place the
latest firmware on all drives.
continued