Table 3-19, Event Messages, Event Type, Recommended Action, Processor, Power Subsystem
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
3-56 Compaq ProLiant DL580 Server Maintenance and Service Guide Table 3-19 Event Messages continued Event Type Event Message Processor Correctable Error Threshold exceeded Processor Correctable Error Threshold passed (Slot X, Socket X) Uncorrectable Error Unrecoverable Host Bus Data Parity Error Host Bus Error Unrecoverable Host Bus Address Parity Error PCI Bus Error Power Subsystem Power Supply Failure Power Supply Inserted Power Supply Removed Power Supply Not Redundant System Configuration Battery Low AC Voltage Problem Power AC Overload PCI Bus Error (Slot X, Bus X, Device X, Function X) System Power Supply Failure (Power Supply X) System Power Supply Inserted (Power Supply X) System Power Supply Removed (Power Supply X) System Power Supplies Not Redundant Real-Time Clock Battery Failing System AC Power Problem (Power Supply X) System AC Power Overload (Power Supply X) Automatic Server Recovery-2 System Stops Responding ASR Lockup Detected: Cause Recommended Action Replace the processor. Replace the processor. Call the Compaq authorized service provider or Compaq technical support for diagnosis. Power down PCI slot and replace board. Replace power supply. None None Add power supply. Replace battery. Check the input power voltage. Change the input power to 220 V. Add an additional power supply, or replace with one able to supply present load. Reduce the load. Call the Compaq authorized service provider or Compaq technical support for diagnosis. continued