Compaq DL580R01 Service Guide - Page 86
Run Array Diagnostic Utility, Cables Attached
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Diagnostics and Troubleshooting 3-17 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1785-External None Cable(s) Attached to Wrong SCSI Port Connector(s). Drive positions None cannot be changed during Capacity Expansion. Drive positions None appear to have changed. Configuration None information indicates drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller. Configuration None information indicates drives were configured on a controller with a newer firmware version. Probable Source of Problem Configuration error Configuration error Configuration error Configuration error Recommended Action Power down system and swap SCSI power connectors to prevent data loss. Run Array Diagnostic Utility (ADU) if previous positions are unknown. Then power down system and move drives to their original positions. Run Array Diagnostic Utility (ADU) if previous positions are unknown. Then power down the system and move drives to their original positions. To avoid data loss, power down and reattach drives to the original controller. Configuration error To avoid data loss, reattach drives to original controller or upgrade controller firmware to the version of the original controller using Option ROMPaq. Press F1 to resume. continued