Compaq DL580R01 Service Guide - Page 96
– 699, Diskette Drive Test Error Codes, Table 3-8
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Diagnostics and Troubleshooting 3-27 600 - 699, Diskette Drive Test Error Codes The 600 series of diagnostic error codes identifies failures with the diskette, diskette drive, or system board functions. Corrective action may require replacement of the diskette drive or the system board assembly. Table 3-8 Diskette Drive Test Error Codes Error Code 600-XX 601-XX 602-XX 603-XX 604-XX 605-XX 606-XX 607-XX 608-XX 609-XX 610-XX 694-XX 697-XX 698-XX 699-XX Description Diskette ID drive types test failed. Diskette format failed. Diskette read test failed. Diskette write/read/compute test failed. Diskette random seek test failed. Diskette ID media failed. Diskette speed test failed. Diskette wrap test failed. Diskette write protect test failed. Diskette reset controller test failed. Diskette change line test failed. Pin 34 is not cut on 360-KB diskette drive. Diskette type error. Diskette drive speed not within limits. Diskette drive/media ID error. Recommended Action 1. Replace the diskette and retest. 2. Check and/or replace the diskette power and signal cables, then retest. 3. Replace the diskette drive and retest. 4. Replace the system board and retest. 1. Replace the media and retest. 2. Run the Configuration Utility and retest.