Compaq DL580R01 Service Guide - Page 118
Message, Description, Recommended Action, WARNING, SOLUTION: Upgrade
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Diagnostics and Troubleshooting 3-49 Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Swapped cables or Configuration error detected. The configuration information on the attached drives is not backward compatible with this controller's firmware. The current firmware version on the controller cannot interpret the configuration information on the attached drives. Upgrade the firmware. -Or- If that does not solve the problem, move the drives back to the original controller. SOLUTION: Upgrade the firmware on this controller. If this doesn't solve the problem then power down system then move drives back to the original controller. Swapped cables or Configuration error detected. The maximum logical volume count X was exceeded during logical volume addition. All logical volumes beyond X have been lost and cannot be recovered. SOLUTION: Identify the drives that contain the lost logical volumes. Move those drives to another controller where the logical volumes can be recreated. NOTE! If a drive contains a valid logical volume and a lost logical volume, then do not move that drive to another controller. More logical drives were created than are supported on this controller, causing lost logical drive volumes. Identify the drives containing lost volumes, and move them to another controller so the lost volumes can be recreated. WARNING: Do not move a drive if it also contains valid volume data. This process causes all valid data to be destroyed! continued