Compaq DL580R01 Service Guide - Page 93
– 299, Memory Test Error Codes, Table 3-4
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
3-24 Compaq ProLiant DL580 Server Maintenance and Service Guide 200 - 299, Memory Test Error Codes The 200 series of diagnostic error codes identifies failures with the memory subsystem. Corrective action may require replacement of the memory expansion board, the memory modules, or the processor assembly. Table 3-4 Memory Test Error Codes Error Code 200-XX 201-XX 202-XX 203-XX 204-XX 205-XX 206-XX 207-XX 208-XX 210-XX Description Invalid memory configuration. Memory machine ID test failed. Memory system ROM checksum failed. Memory write/read test failed. Memory address test failed. Walking I/O test failed. Increment pattern test failed. Invalid memory configuration- check DIMM installation. DIMMs installed have 8K refresh. Invalid memory speed detected- check DIMM installation. Slow DIMMs may cause data loss. Random pattern test failed. Recommended Action Reinsert memory modules in correct location and retest. 1. Replace the system ROM and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. 1. Replace the memory module and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest. Replace DIMMs. Replace with DIMMs faster than 60 ns. 1. Replace the memory module and retest. 2. Replace the processor board and retest. 3. Replace the memory expansion board and retest.