Compaq DL580R01 Service Guide - Page 116
SOLUTION: This may, Wide SCSI transfer
UPC - 720591221416
View all Compaq DL580R01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
Diagnostics and Troubleshooting 3-47 Table 3-18 Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Storage enclosure on SCSI bus X indicated that the fan module is unplugged. A fan in the external storage unit is Check and reseat all fan connections securely. not connected properly. SOLUTION: Make sure the fan module is properly connected. Storage enclosure on SCSI bus X - Wide SCSI transfer failed. SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable. A cable on bus X has failed. 1. Replace the failed cable. 2. If that does not solve the problem, contact your Compaq authorized service provider. Swapped cables or Configuration error detected. A configured array of drives was moved from another controller that supported more drives than this controller supports. You have exceeded the maximum number of drives supported for this controller and the attached controller was not part of the original array configuration. 1. Upgrade the firmware on this controller. 2. If the problem is not resolved: Replace this controller with the original controller. -Or- Replace this controller with a new controller that supports the number of drives in the array. SOLUTION: Upgrade the firmware on this controller. If this doesn't solve the problem, then power down system and move the drives back to the original controller. continued