HP StorageWorks 1606 Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 100

TABLE 14, lists and describes each item in the port detail report.

Page 100 highlights

9 Port Detail report 216 VE HEALTHY 061:19 217 VE HEALTHY 061:19 218 VE HEALTHY 061:19 219 VE HEALTHY 003:37 220 VE HEALTHY 002:48 221 VE HEALTHY 061:19 222 VE HEALTHY 061:19 223 VE HEALTHY 061:19 NOTE Output of the Port Detail Report depends on the ports that belong to the current Admin Domain context. If a port does not belong to the current Admin Domain, nothing other than port number is displayed for that port. Example: "000 Not a member of current Admin Domain Table 14 lists and describes each item in the port detail report. TABLE 14 Port detail report columns Report item Description LFA Link Loss: the number of link loss occurrences out of range for a specified time period. LSY Sync Loss: the number of sync loss occurrences out of range for a specified time period. LSI Signal Loss: the number of signal loss occurrences out of range for a specified time period. PER Protocol Error: the number of protocol errors out of range for a specified time period. INW Invalid word. The number of invalid words out of range for a specified time period. CRC Invalid CRC: the number of CRC errors out of range for a specified time period. PSC Port hardware state changed too often because of fabric reconfiguration. BLP Buffer limited port: the switch status changes when a port is in a buffer limited mode based on the switch status policy. STM SFP temperature is out of specifications. SRX SFP receive power is out of specifications. STX SFP transmit power is out of specifications. SCU SFP current is out of specifications. SVO SFP voltage is out of specifications. 76 Fabric Watch Administrator's Guide 53-1001342-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

76
Fabric Watch Administrator’s Guide
53-1001342-01
Port Detail report
9
216
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
217
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
218
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
219
VE
HEALTHY
003:37
-
-
-
-
-
-
-
-
-
-
-
-
-
220
VE
HEALTHY
002:48
-
-
-
-
-
-
-
-
-
-
-
-
-
221
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
222
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
223
VE
HEALTHY
061:19
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Output of the Port Detail Report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than port number is
displayed for that port.
Example:
“000
----------------Not a member of current Admin Domain-------------------”
Table 14
lists and describes each item in the port detail report.
TABLE 14
Port detail report columns
Report item
Description
LFA
Link Loss: the number of link loss occurrences out of range for a specified time period.
LSY
Sync Loss: the number of sync loss occurrences out of range for a specified time period.
LSI
Signal Loss: the number of signal loss occurrences out of range for a specified time period.
PER
Protocol Error: the number of protocol errors out of range for a specified time period.
INW
Invalid word. The number of invalid words out of range for a specified time period.
CRC
Invalid CRC: the number of CRC errors out of range for a specified time period.
PSC
Port hardware state changed too often because of fabric reconfiguration.
BLP
Buffer limited port: the switch status changes when a port is in a buffer limited mode based
on the switch status policy.
STM
SFP temperature is out of specifications.
SRX
SFP receive power is out of specifications.
STX
SFP transmit power is out of specifications.
SCU
SFP current is out of specifications.
SVO
SFP voltage is out of specifications.