HP StorageWorks 1606 Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 93

Advanced configuration options

Page 93 highlights

Advanced configuration options 8 Advanced configuration options To customize Fabric Watch monitoring to suit your environment, use the advanced configuration options, which are listed in Table 12. Table 12 describes the customization options displayed at the end of the Advanced Configuration menu. With the exception of the last option, which exits advanced configuration mode, each option has similar behavior. For each option, one or two lines will appear, prompting you to accept the new setting information, and, after the information has been provided, the entire screen will refresh to display the updated information. TABLE 12 Option Advanced configuration options Effect Input information change behavior type change behavior interval change threshold boundary level change custom unit change custom time base change custom low change custom high change custom buffer apply threshold boundary changes cancel threshold boundary changes change threshold alarm level Changes the behavior type of a single element to either Triggered or Continuous. The change is volatile because this option is not saved to flash memory. Every time the switch is rebooted, this option is reset. The element index and the required behavior type Changes the behavior interval for a single element. The change is volatile because this option is not saved to flash memory. Every time the switch is rebooted, this option is reset. This value is effective only when the behavior type is set to continuous. The element index and the required behavior interval, in seconds Changes between the factory default The required threshold column and custom threshold information. Obsolete Obsolete Changes the time base for the area, The required time base but only affects the custom column. Changes the low setting for the The required low threshold, in the units threshold, but only affects the custom defined by the area column. Changes the high setting for the The required high threshold, in the units threshold, but only affects the custom defined by the area column. Changes the buffer size for the The required buffer size, in the units threshold, but only affects the custom defined by the area column. Confirms the changes made to the threshold information. This must be done to retain the changes made. None Returns the boundary information to None the last confirmed state. Changes between the factory default and custom event settings for the area. The required event setting column Fabric Watch Administrator's Guide 69 53-1001342-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

Fabric Watch Administrator’s Guide
69
53-1001342-01
Advanced configuration options
8
Advanced configuration options
To customize Fabric Watch monitoring to suit your environment, use the
advanced configuration
options, which are listed in
Table 12
.
Table 12
describes the customization options displayed at the end of the Advanced Configuration
menu. With the exception of the last option, which exits advanced configuration mode, each option
has similar behavior. For each option, one or two lines will appear, prompting you to accept the new
setting information, and, after the information has been provided, the entire screen will refresh to
display the updated information.
TABLE 12
Advanced configuration options
Option
Effect
Input information
change behavior type
Changes the behavior type of a single
element to either Triggered or
Continuous. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
The element index and the required
behavior type
change behavior interval
Changes the behavior interval for a
single element. The change is volatile
because this option is not saved to
flash memory. Every time the switch
is rebooted, this option is reset.
This value is effective
only
when the
behavior type is set to
continuous
.
The element index and the required
behavior interval, in seconds
change threshold boundary
level
Changes between the factory default
and custom threshold information.
The required threshold column
change custom unit
Obsolete
Obsolete
change custom time base
Changes the time base for the area,
but only affects the custom column.
The required time base
change custom low
Changes the low setting for the
threshold, but only affects the custom
column.
The required low threshold, in the units
defined by the area
change custom high
Changes the high setting for the
threshold, but only affects the custom
column.
The required high threshold, in the units
defined by the area
change custom buffer
Changes the buffer size for the
threshold, but only affects the custom
column.
The required buffer size, in the units
defined by the area
apply threshold boundary
changes
Confirms the changes made to the
threshold information. This must be
done to retain the changes made.
None
cancel threshold boundary
changes
Returns the boundary information to
the last confirmed state.
None
change threshold alarm level
Changes between the factory default
and custom event settings for the
area.
The required event setting column