B Class default settings Port class default settings Table 20 provides default settings (per minute) for areas in the Port class. TABLE 20 Port class default settings Area Description Default threshold Default alarm settings settings Threshold state Class 3 Discards Class 3 discards frames due to timeout or destination unreachable. Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Invalid CRC Count Monitors the number Unit: Errors of CRC errors Time Base: minute Low: 0 High: 1000 Buffer: 100 Invalid Transmission Word Monitors the number Unit: Errors of invalid words Time Base: minute transmitted Low: 0 High: 1000 Buffer: 100 Link Failure Count Monitors the number Unit: Errors of link failures Time Base: minute Low: 0 High: 500 Buffer: 50 Loss of Signal Count Monitors the number Unit: Errors of signal loss errors Time Base: minute Low: 0 High: 5 Buffer: 0 Loss of Synchronization Count Monitors the number Unit: Errors of loss of Time Base: minute synchronization Low: 0 errors High: 500 Buffer: 50 Link Reset Monitors the number Unit: Errors of link resets sent by Time Base: minute a given port (LR-Out) Low: 0 and received on a High: 500 given port (LR-In). Buffer: 50 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Primitive Sequence Protocol Error Monitors the number Unit: Errors of primitive sequence Time Base: minute errors Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range 92 Fabric Watch Administrator's Guide 53-1001342-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

92
Fabric Watch Administrator’s Guide
53-1001342-01
Class default settings
B
Port class default settings
Table 20
provides default settings (per minute) for areas in the Port class.
TABLE 20
Port class default settings
Area
Description
Default threshold
settings
Default alarm settings
Threshold state
Class 3 Discards
Class 3 discards
frames due to
timeout or
destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer:
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid CRC Count
Monitors the number
of CRC errors
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Word
Monitors the number
of invalid words
transmitted
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count
Monitors the number
of link failures
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal Count
Monitors the number
of signal loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of
Synchronization
Count
Monitors the number
of loss of
synchronization
errors
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Reset
Monitors the number
of link resets sent by
a given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the number
of primitive sequence
errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range