HP StorageWorks 1606 Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 112

Environment class default settings, TABLE 16

Page 112 highlights

B Class default settings Environment class default settings Table 16 provides default Environment class settings for all switches. Check the appropriate hardware reference manual for differences in actual environmental requirements. NOTE Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring and the switch status is calculated based on the fan status reported by EM. TABLE 16 Area Environment class default settings Description Default threshold settings Temperature Monitors switch temperature in Celsius Unit: degrees C Time Base: none Brocade 200E Low: 0 High: 60 Buffer: 10 Brocade 300 Low: 0 High: 50 Buffer: 10 Brocade 4100 Low:0 High: 60 Buffer: 10 Brocade 4900 Low: 0 High: 47 Buffer: 10 Brocade 5000 Low:0 High: 60 Buffer: 10 Brocade 5100 Low: 0 High: 63 Buffer: 10 Brocade 5300 Low: 0 High: 48 Buffer: 10 Brocade 7500 Low: 0 High: 63 Buffer: 10 Brocade 7600 Low: 0 High: 63 Buffer: 10 Default alarm settings Threshold state Changed: 0 Below: 3 Above: 3 In-Between: 3 Informative Out-of-range Out-of-range In_range (Same setting for all (Same setting for all devices) devices except Brocade DCX-4S) 88 Fabric Watch Administrator's Guide 53-1001342-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

88
Fabric Watch Administrator’s Guide
53-1001342-01
Class default settings
B
Environment class default settings
Table 16
provides default Environment class settings for all switches. Check the appropriate
hardware reference manual for differences in actual environmental requirements.
NOTE
Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring
and the switch status is calculated based on the fan status reported by EM.
TABLE 16
Environment class default settings
Area
Description
Default threshold
settings
Default alarm settings
Threshold state
Temperature
Monitors switch
temperature in
Celsius
Unit: degrees C
Time Base: none
Brocade 200E
Low: 0
High: 60
Buffer: 10
Changed: 0
Below: 3
Above: 3
In-Between: 3
(Same setting for all
devices)
Informative
Out-of-range
Out-of-range
In_range
(Same setting for all
devices except
Brocade DCX-4S)
Brocade 300
Low: 0
High: 50
Buffer: 10
Brocade 4100
Low:0
High: 60
Buffer: 10
Brocade 4900
Low: 0
High: 47
Buffer: 10
Brocade 5000
Low:0
High: 60
Buffer: 10
Brocade 5100
Low: 0
High: 63
Buffer: 10
Brocade 5300
Low: 0
High: 48
Buffer: 10
Brocade 7500
Low: 0
High: 63
Buffer: 10
Brocade 7600
Low: 0
High: 63
Buffer: 10