HP Superdome SX2000 User Service Guide, Seventh Edition - HP Integrity Superdo - Page 146

Table A-2 Power and OL* LEDs, Meaning, State, Driven By, Location

Page 146 highlights

Table A-2 Power and OL* LEDs LED Location Driven By Cell Power Chassis beside cell and Cell LPM on cell Cell Attention Chassis beside cell CLU State Meaning Solid Green HKP, PWR_GOOD Solid Yellow Cell OL* PDHC Post Cell PDHC PM Post On the UGUY board, MOP driven by the PM CLU Post On the UGUY board, SARG driven by the CLU PCI Card cage Chassis behind PCI card CLU Attention cage Link Cable OL* Main Backplane CLU MP Post SBCH SBCH Cabinet and Each fan IO Bay Fans Backplane System Backplane Power Boards PM RPM Hot swap oscillators (HSO) System Backplane RPM 0x0 oxf 0xe->0x1 PDHC Post or run state 0x0 0xf 0xe->0x1 No HKP MOP is reset or dead PM Post or run state 0x0 0xf 0xe->0x1 No HKP CLU is reset or dead CLU Post or run state Solid Yellow Solid Yellow 0x0 0xf 0xe->0x1 PCI card cage OL* LED, Link cable OL* No HKP MP is reset or dead MP Post or run state Solid Green Fan is running and no fault Solid Green Power supply is running Yellow Blinking Power fault Solid Green HSO Supply running Solid Yellow HSO clock fault 146 sx2000 LEDs

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

Table A-2 Power and OL* LEDs
Meaning
State
Driven By
Location
LED
HKP, PWR_GOOD
Solid Green
Cell LPM
Chassis beside cell and
on cell
Cell Power
Cell OL*
Solid
Yellow
CLU
Chassis beside cell
Cell Attention
PDHC Post or run state
0x0
oxf
0xe->0x1
PDHC
Cell
PDHC Post
No HKP
MOP is reset or dead
PM Post or run state
0x0
0xf
0xe->0x1
MOP
On the UGUY board,
driven by the PM
PM Post
No HKP
CLU is reset or dead
CLU Post or run state
0x0
0xf
0xe->0x1
SARG
On the UGUY board,
driven by the CLU
CLU Post
PCI card cage OL* LED,
Solid
Yellow
CLU
Chassis behind PCI card
cage
PCI Card cage
Attention
Link cable OL*
Solid
Yellow
CLU
Main Backplane
Link Cable
OL*
No HKP
MP is reset or dead
MP Post or run state
0x0
0xf
0xe->0x1
SBCH
SBCH
MP Post
Fan is running and no fault
Solid Green
PM
Each fan
Cabinet and
IO Bay Fans
Power supply is running
Power fault
Solid Green
Yellow
Blinking
RPM
System Backplane
Backplane
Power Boards
HSO Supply running
HSO clock fault
Solid Green
Solid
Yellow
RPM
System Backplane
Hot swap
oscillators
(HSO)
146
sx2000 LEDs