Intel S1200BTL Product Specification - Page 140

Sensor Type

Page 140 highlights

Appendix B: Integrated BMC Sensor Tables Intel®Server Board S1200BT TPS Full Sensor Name (Sensor name in SDR) Hard Disk Drive 2 Status (HDD 2 Status) Hard Disk Drive 3 Status (HDD 3 Status) Sensor # Platform Applicability F2h Chassisspecific F3h Chassisspecific Sensor Type Drive Slot 0Dh Drive Slot 0Dh Event/Reading Type Sensor Specific 6Fh Sensor Specific 6Fh Event Offset Triggers Contrib. To System Status 07 - Rebuild/Remap in progress 00 - Drive Presence 01- Drive Fault 02- Predictive Failure 07 - Rebuild/Remap in progress 00 - Drive Presence 01- Drive Fault 02- Predictive Failure 07 - Rebuild/Remap in progress Degraded OK Degraded Degraded Degraded OK Degraded Degraded Degraded Assert/Deassert As and De As and De Readable Event Data Value/Offsets - Trig Offset - Trig Offset Rearm Stand-by A X A 128 Revision 1.0 Intel order number G13326-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

Appendix B: Integrated BMC Sensor Tables
Intel®
Server Board S1200BT TPS
Revision 1.0
Intel order number G13326-003
128
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading Type
Event Offset Triggers
Contrib. To System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-by
07 - Rebuild/Remap in
progress
Degraded
Hard Disk Drive 2
Status
(HDD 2 Status)
F2h
Chassis-
specific
Drive Slot
0Dh
Sensor Specific
6Fh
00 - Drive Presence
OK
As and
De
Trig
Offset
A
X
01- Drive Fault
Degraded
02- Predictive Failure
Degraded
07 - Rebuild/Remap in
progress
Degraded
Hard Disk Drive 3
Status
(HDD 3 Status)
F3h
Chassis-
specific
Drive Slot
0Dh
Sensor Specific
6Fh
00 - Drive Presence
OK
As and
De
Trig
Offset
A
01- Drive Fault
Degraded
02- Predictive Failure
Degraded
07 - Rebuild/Remap in
progress
Degraded