Intel S1200BTL Product Specification - Page 83

Advanced > Mass Storage Controller - memory compatibility

Page 83 highlights

Intel®Server Board S1200BT TPS BIOS User Interface Comments: Information only, for S1200 boards: Displays the state of each DIMM socket present on the board. Each DIMM socket field reflects one of the following possible states:  Installed - There is a DDR3 DIMM installed in this slot.  Not Installed - There is no DDR3 DIMM installed in this slot.  Failed - The DDR3 DIMM installed in this slot has been disabled by the BIOS in order to optimize the memory configuration.  Disabled - The DDR3 DIMM installed in this slot is faulty or malfunctioning. 6.5.2.6 Mass Storage Controller Configuration The Mass Storage Configuration screen allows the user to configure the SATA or SAS controller when it is present on the server board, midplane or backplane of an Intel® system. To access this screen from the Main screen, select Advanced > Mass Storage Controller Configuration. To move to another screen, press the key to return to the Advanced screen, then select the desired screen. Advanced Mass Storage Controller Configuration Intel® SAS Entry RAID Module Configure Intel® SAS Entry RAID Module Onboard SATA Controller Configure SATA Mode Enabled/Disabled IT/IR RAID/Intel® ESRTII Enabled/Disabled ENHANCED/COMPATIBILITY/AHCI/SW RAID ► SATA Port 0 ► SATA Port 1 ► SATA Port 2 ► SATA Port 3 ► SATA Port 4 ► SATA Port 5 Not Installed/ Not Installed/ Not Installed/ Not Installed/ Not Installed/ Not Installed/ Figure 19. Mass Storage Controller Configuration Screen 6.5.2.7 Serial Port Configuration The Serial Port Configuration screen allows the user to configure the Serial A [COM 1] and Serial B [COM2] ports. To access this screen from the Main screen, select Advanced > Serial Port Configuration. To move to another screen, press the key to return to the Advanced screen, then select the desired screen. Revision 1.0 71 Intel order number G13326-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

Intel®
Server Board S1200BT TPS
BIOS User Interface
Revision 1.0
Intel order number G13326-003
71
Comments:
Information only, for S1200 boards: Displays the state of each
DIMM socket present on the board. Each DIMM socket field reflects one of the following
possible states:
Installed
There is a DDR3 DIMM installed in this slot.
Not Installed
There is no DDR3 DIMM installed in this slot.
Failed
The DDR3 DIMM installed in this slot has been disabled by the
BIOS in order to optimize the memory configuration.
Disabled
The DDR3 DIMM installed in this slot is faulty or malfunctioning.
6.5.2.6
Mass Storage Controller Configuration
The Mass Storage Configuration screen allows the user to configure the SATA or SAS
controller when it is present on the server board, midplane or backplane of an Intel
®
system.
To access this screen from the
Main
screen, select
Advanced > Mass Storage Controller
Configuration
. To move to another screen, press the
<Esc>
key to return to the
Advanced
screen, then select the desired screen.
Advanced
Mass Storage Controller Configuration
Intel
®
SAS Entry RAID Module
Enabled
/Disabled
Configure Intel
®
SAS Entry RAID Module
IT/IR RAID
/Intel
®
ESRTII
Onboard SATA Controller
Enabled
/Disabled
Configure SATA Mode
ENHANCED
/COMPATIBILITY/AHCI/SW RAID
SATA Port 0
Not Installed/<Drive Info.>
SATA Port 1
Not Installed/<Drive Info.>
SATA Port 2
Not Installed/<Drive Info.>
SATA Port 3
Not Installed/<Drive Info.>
SATA Port 4
Not Installed/<Drive Info.>
SATA Port 5
Not Installed/<Drive Info.>
Figure 19. Mass Storage Controller Configuration Screen
6.5.2.7
Serial Port Configuration
The Serial Port Configuration screen allows the user to configure the Serial A [COM 1] and
Serial B [COM2] ports.
To access this screen from the
Main
screen, select
Advanced
>
Serial Port Configuration
.
To move to another screen, press the
<Esc>
key to return to the
Advanced
screen, then select
the desired screen.