Intel S1200BTL Product Specification - Page 47

Basic and Optional Advanced Management Features - firmware update

Page 47 highlights

Intel®Server Board S1200BT TPS Platform Management o Human-readable SEL o Additional system configurability o Additional system monitoring capability o Enhanced on-line help  Enhancements to KVM redirection o Support for higher resolution  Management support for PMBus rev1.2 compliant power supplies  Integrated BMC firmware reliability enhancements: o Redundant Integrated BMC boot blocks to avoid possibility of a corrupted boot block resulting in a scenario that prevents a user from updating the Integrated BMC. 4.2 Basic and Optional Advanced Management Features This section explains the advanced management features supported by the Integrated Baseboard Management Controller (Integrated BMC) firmware. This section explains the advanced management features supported by the BMC firmware. Error! Reference source not found. lists basic and advanced feature support. Individual features may vary by platform. For more information, refer to Appendix D. Table 11. Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State Retention ARP/DHCP Support PECI Thermal Management Support E-mail Alerting Embedded Web Server SSH Support Integrated KVM Integrated Remote Media Redirection Local Directory Access Protocol (LDAP) Intel® Intelligent Power Node Manager Support*** SMASH CLP Basic* X X X X X X X X X X X X X X X X X Advanced** X X X X X X X X X X X X X X X X X X X * Basic management features provided by Integrated BMC **Advanced management features available with optional Intel® Remote Management Module 4 ***Intel® Intelligent Power Node Manager Support requires PMBus-compliant power supply Revision 1.0 35 Intel order number G13326-003

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

Intel®
Server Board S1200BT TPS
Platform Management
Revision 1.0
Intel order number G13326-003
35
o
Human-readable SEL
o
Additional system configurability
o
Additional system monitoring capability
o
Enhanced on-line help
Enhancements to KVM redirection
o
Support for
higher resolution
Management support for PMBus rev1.2 compliant power supplies
Integrated BMC firmware reliability enhancements:
o
Redundant Integrated BMC boot blocks to avoid possibility of a corrupted boot
block resulting in a scenario that prevents a user from updating the Integrated
BMC.
4.2
Basic and Optional Advanced Management Features
This section explains the advanced management features supported by the Integrated
Baseboard Management Controller (Integrated BMC) firmware.
This section explains the advanced management features supported by the BMC firmware.
Error! Reference source not found.
lists basic and advanced feature support. Individual
features may vary by platform. For more information, refer to Appendix D.
Table 11. Basic and Advanced Management Features
Feature
Basic*
Advanced**
IPMI 2.0 Feature Support
X
X
In-circuit BMC Firmware Update
X
X
FRB 2
X
X
Chassis Intrusion Detection
X
X
Fan Redundancy Monitoring
X
X
Hot-Swap Fan Support
X
X
Acoustic Management
X
X
Diagnostic Beep Code Support
X
X
Power State Retention
X
X
ARP/DHCP Support
X
X
PECI Thermal Management Support
X
X
E-mail Alerting
X
X
Embedded Web Server
X
X
SSH Support
X
X
Integrated KVM
X
Integrated Remote Media Redirection
X
Local Directory Access Protocol (LDAP)
X
X
Intel
®
Intelligent Power Node Manager
Support***
X
X
SMASH CLP
X
X
* Basic management features provided by Integrated BMC
**Advanced management features available with optional Intel
®
Remote Management Module 4
***Intel
®
Intelligent Power Node Manager Support requires PMBus-compliant power supply