Brother International MFC-7050C Service Manual - Page 114
Cr4Ta
View all Brother International MFC-7050C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
3.4 Operational Check of Control Panel PCB • Function This function allows you to check the control panel PCB for normal operation. • Operating Procedure (1) Press the 1 and 3 keys in this order in the initial stage of the maintenance mode. The "00 " will appear on the LCD. (2) Press the keys and buttons in the order designated in the illustration shown below. The LCD shows the corresponding number in decimal notation each time a key or button is pressed. Check that the displayed number is correct by referring to the illustration below. If a key or button is pressed out of order, the equipment beeps and displays the "INVALID OPERATE" on the LCD. To return to the status ready to accept key & button entry for operational check, press the Stop key. (3) After the last number key or button is pressed, the equipment beeps and returns to the initial stage of the maintenance mode. To terminate this operation, press the Stop key. The equipment returns to the initial stage of the maintenance mode. brother 7O5OC Function Se,t qp CHco)ok - alume 1 BC.?") a?DDEF Hold Gm JKL MNO C li?Daga Redial / Pause Pons TUV WXYZ oCr4Ta Speed Dial C® COEDg?)0 'Shift ' 1) 0 Fine 0 FAX I Photo .1 Msg Ctr 0 S.Fine 0 FAX/TEL Tel-index Mn Mode Broadcast 01 02 03 04 13 14 15 05 06 07 08 17 8 9 20 09 10 11 - 2i. 21 22 23 _C) CD Ct Message Center Voice 0 0 Fax Record Erase Play (03 (03 (O) Color Printer On/Off Line Reset Priority Ink Management (O) (g) (O) (O) Enlarge Reduce (g) (g) Sort Photo C48) C-CP Stop O Copy Start O Key & Button Entry Order V - 18