Page 64 highlights
1.16 Main PCB and Insulation Film (1) Disconnect the centro harnesses (1 and 2) and power supply harnesses (1 and 2) from the main PCB. (2) Disconnect the following harnesses and flat cables from the main PCB: • Carrier flat cables • Ink empty sensor harness • Carrier transport motor harness • Paper feed motor harness • NCU harness • Video capture harness Carrier flat cables Ferrite core Ink empty sensor harness JN/ Carrier transport motor harness Carrier flat cables Centro 1 harness Centro 2 harness Main PCB ri Power supply 1 harness (Rear) Power supply 2 harness Paper feed motor harness Video capture harness NCU harness Ink empty sensor harness Cover sensor harness Panel-main (Top) harness (Not used.) (Not used.) Centro 1 harness Centro 2 harness Scanner motor harness r P11 P12 P13 P15 L r P14 P16 / P10 O 0 Video capture harness CIS harness Carrier flat cables P18 P5 `)J Carrier transport 0 P0 motor harness Power supply 1 harness Power supply 2 harness Speaker harness (Bottom) IV - 32 NCU harness Battery harness Hook switch harness Paper feed motor harness