Brother International MFC-7050C Service Manual - Page 40
Reassembling
View all Brother International MFC-7050C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
1.3 Control Panel ASSY (1) Slightly open the control panel ASSY. (2) Push the right and left arms of the control panel ASSY outwards (in the direction of arrow 0) with your thumbs and open the control panel ASSY further (arrow 0) to unhook those arms from bosses "x" provided on the scanner frame ASSY. Then slide the control panel ASSY to the front (arrow CD) to release its bosses "y" from the grooves of the scanner frame ASSY. (3) Slightly lift up the control panel ASSY and disconnect the panel-main harness from the control panel PCB. Control panel ASSY BOSS "y" Arm 0 --- 0 -"so 0 0 0 ° e' 0 0 o O o. o Op I g Arm of control panel ASSY Boss "y" of control panel ASSY Boss "x" of scanner frame ASSY Panel-main harness Control panel ASSY Control panel PCB Scanner frame ASSY • Reassembling Notes • Make sure that the panel-main harness is not slack or pinched between the scanner frame and panel rear cover. IV - 8