HP 6125XLG R2306-HP 6125XLG Blade Switch IP Multicast Command Reference - Page 152
c-rp (IPv6 PIM view
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
priority priority: Specifies a priority for the C-BSR, in the range of 0 to 255. The default setting is 64. A larger value indicates a higher priority. Usage guidelines The IPv6 address of a C-BSR must be the IPv6 address of a local IPv6 PIM enabled interface on the C-BSR. Otherwise, the configuration does not take effect. If you execute this command for a zone multiple times, the most recent configuration takes effect. You can configure the same C-BSR for different zones. Examples # Configure the interface with the IPv6 address of 1101::1 as the C-BSR for the global-scoped zone. system-view [Sysname] ipv6 pim [Sysname-pim6] c-bsr 1101::1 c-rp (IPv6 PIM view) Use c-rp to configure a candidate-RP (C-RP). Use undo c-rp to remove the configuration of a C-RP. Syntax c-rp ipv6-address [ advertisement-interval adv-interval | { group-policy acl6-number | scope scope-id } | holdtime hold-time | priority priority ] * undo c-rp ipv6-address Default No C-RPs are configured. Views IPv6 PIM view Predefined user roles network-admin Parameters ipv6-address: Specifies the IPv6 address of a C-RP. advertisement-interval adv-interval: Specifies an interval (in seconds) between two C-RP-Adv messages, in the range of 1 to 65535. The default value is 60 seconds. group-policy acl6-number: Specifies an IPv6 basic ACL in the range of 2000 to 2999 to filter IPv6 multicast groups. The C-RP is designated only to IPv6 multicast groups that match a permit statement in the ACL. If the group-policy acl6-number option is not specified, or if the specified ACL does not exist or does not have any valid permit statement, the C-RP is designated to all IPv6 multicast groups FF00::/8. scope scope-id: Specifies the ID of an IPv6 admin-scoped zone, in the range of 3 to 15. holdtime hold-time: Specifies a lifetime (in seconds) for the C-RP, in the range of 1 to 65535. The default value is 150 seconds. priority priority: Specifies a priority for the C-RP, in the range of 0 to 255. The default setting is 192. A larger value indicates a lower priority. 146