HP 6125XLG R2306-HP 6125XLG Blade Switch IP Multicast Command Reference - Page 191
IPv6 PIM view
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 191 highlights
Views IPv6 PIM view Predefined user roles network-admin Parameters interval: Sets the global interval (in seconds) for sending the join/prune messages, in the range of 0 to 18000. A value of 0 means that no join or prune messages are sent. Usage guidelines You can set the interval for sending the join/prune messages in IPv6 PIM view or interface view. The configurations made in IPv6 PIM view are effective on all interfaces, and the configurations made in interface view are effective on only the current interface. If you set the interval in both IPv6 PIM view and interface view, the configuration in interface view always takes precedence. Examples # Set the global interval for sending the join/prune messages to 80 seconds. system-view [Sysname] ipv6 pim [Sysname-pim6] timer join-prune 80 Related commands ipv6 pim timer join-prune 185