Page 171 highlights
Appendix A Specifications Environmental Requirements The specifications listed below can vary if you install a mass storage device in your HP NetServer that has more stringent environmental limits. Ensure the operating environment is suitable for all mass storage devices in use. Table A-5. Environmental Requirements BTU 1845 BTU/hr maximum Temperature Operating Non-operating Humidity Operating Non-operating Altitude Operating Non-operating 5° C to 35°C (41°F to 95° F) -40° C to +65° C (-40° F to +149° F) 20% to 80% relative humidity (non-condensing) 5% to 95% relative humidity (non-condensing) -30 to 3,045 m (10,000 ft) -30 to 12,180 m (40,000 ft) Acoustic Emissions Sound Level: (LpA) < 50 dB(A) bystander position 163
Appendix A
Specifications
163
Environmental Requirements
The specifications listed below can vary if you install a mass storage device in
your HP NetServer that has more stringent environmental limits. Ensure the
operating environment is suitable for all mass storage devices in use.
Table A-5. Environmental Requirements
BTU
1845 BTU/hr maximum
Temperature
Operating
5° C to 35°C
(41°F to 95° F)
Non-operating
–40° C to +65° C
(–40° F to +149° F)
Humidity
Operating
20% to 80% relative humidity
(non-condensing)
Non-operating
5% to 95% relative humidity
(non-condensing)
Altitude
Operating
-30 to 3,045 m (10,000 ft)
Non-operating
-30 to 12,180 m (40,000 ft)
Acoustic Emissions
Sound Level: (LpA) < 50 dB(A) bystander position