Chapter 8 Rack-Mounting the HP NetServer Preparing the Rack The column adapters and rack nuts must be connected to the rack before mounting the slide mechanism. Once the slides are correctly mounted, then the HP NetServer LC 2000r can be installing into the rack. A cardboard rack mounting template comes with the HP NetServer. The template identifies the column adapter and rack nut locations on the rack. HP NetServer Rack Mount Parts List Ensure the rack-mounting kit provided with the HP NetServer contains the following parts: Table 8-1. Parts for Rack Mount Kit Quantity 2 4 12 6 2 1 Description Slides Rack Nuts Rack Nut Screws (M5 x 16mm) Screws for Slides (8-32 x ¼ inch, 4 panhead and 2 flathead) Column Adapters Template Marking the Rack and Attaching Rack Nuts Use this section to mark the front columns and attach the rack nuts to the rear columns of the HP System/E or HP System/U rack. The column adapters attach to the front columns and the slides are attached to the column adapters and the rack nuts to hold the NetServer's slides in place. The rack template and marking pen are used to identify and mark the locations on the columns. CAUTION If other rack components are to be mounted in the rack below the HP NetServer, install those components before starting to mount the NetServer. NOTE Use the HP Rack Configuration Tools to determine where in the rack to mount the HP NetServer. The tools are available at: http: //www.hp.com/netserver/support 82

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

Chapter 8
Rack-Mounting the HP NetServer
82
Preparing the Rack
The column adapters and rack nuts must be connected to the rack before mounting
the slide mechanism. Once the slides are correctly mounted, then the HP
NetServer LC 2000r can be installing into the rack. A cardboard rack mounting
template comes with the HP NetServer.
The template identifies the column
adapter and rack nut locations on the rack.
HP NetServer Rack Mount Parts List
Ensure the rack-mounting kit provided with the HP NetServer contains the
following parts:
Table 8-1. Parts for Rack Mount Kit
Quantity
Description
2
Slides
4
Rack Nuts
12
Rack Nut Screws (M5 x 16mm)
6
Screws for Slides (8-32 x ΒΌ inch, 4 panhead and 2 flathead)
2
Column Adapters
1
Template
Marking the Rack and Attaching Rack Nuts
Use this section to mark the front columns and attach the rack nuts to the rear
columns of the HP System/E or HP System/U rack. The column adapters attach to
the front columns and the slides are attached to the column adapters and the rack
nuts to hold the NetServer's slides in place. The rack template and marking pen
are used to identify and mark the locations on the columns.
CAUTION
If other rack components are to be mounted in the rack below
the HP NetServer, install those components before starting to
mount the NetServer.
NOTE
Use the
HP Rack Configuration Tools
to determine where in
the rack to mount the HP NetServer. The tools are available at:
http: //www.hp.com/netserver/support