HP LH4r HP Netserver LC 2000 Installation Guide - Page 70

Boot Priority

Page 70 highlights

Chapter 6 Installing Additional Boards Boot Priority This section details the HP NetServer's boot order by highest to lowest priority. The NetServer's boot order (BIOS search order for a boot drive) should be considered when selecting a slot on the system board. This is especially important if you are installing a SCSI disk controller board. The disk controller's boot priority is set by the board's slot location. See Figure 6-1. The on-board SCSI consists of two channels, A and B. Channel A is typically used to control the Hot Swap SCSI drives. Channel B is typically used to control the internal non-hot swap SCSI drives. On each SCSI channel, the system scans for a boot device starting at device ID 0 and works up from there. By default the NetServer searches for boot devices in this order: 1. IDE CD-ROM drive 2. Flexible disk drive 3. SCSI A bus (typically the Hot Swap Mass Storage Cage) 4. SCSI B bus (typically the non-Hot Swap internal SCSI devices) 5. PCI slot P1 6. PCI slot P2 7. PCI slot P3 8. PCI slot P4 9. PCI slot P5 10. PCI slot P6 NOTE The NetServer can be configured to boot from a PCI accessory board or PCI-based DAC, instead of the onboard SCSI channels, by putting the board in one of the PCI slots. The SCSI Configuration Utility can be used to configure the NetServer to skip over the onboard SCSI channels and select a PCI slot instead, when scanning for boot devices. For instructions, refer to the SCSI Configuration Utility in Chapter 10, "Configuring the HP NetServer." 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

Chapter 6
Installing Additional Boards
62
Boot Priority
This section details the HP NetServer’s boot order by highest to lowest priority.
The NetServer’s boot order (BIOS search order for a boot drive) should be
considered when selecting a slot on the system board. This is especially important
if you are installing a SCSI disk controller board. The disk controller’s boot
priority is set by the board’s slot location. See Figure 6-1.
The on-board SCSI consists of two channels, A and B. Channel A is typically
used to control the Hot Swap SCSI drives. Channel B is typically used to control
the internal non-hot swap SCSI drives. On each SCSI channel, the system scans
for a boot device starting at device ID 0 and works up from there.
By default the NetServer searches for boot devices in this order:
1.
IDE CD-ROM drive
2.
Flexible disk drive
3.
SCSI A bus (typically the Hot Swap Mass Storage Cage)
4.
SCSI B bus (typically the non-Hot Swap internal SCSI devices)
5.
PCI slot P1
6.
PCI slot P2
7.
PCI slot P3
8.
PCI slot P4
9.
PCI slot P5
10.
PCI slot P6
NOTE
The NetServer can be configured to boot from a PCI accessory
board or PCI-based DAC, instead of the onboard SCSI
channels, by putting the board in one of the PCI slots. The
SCSI Configuration Utility can be used to configure the
NetServer to skip over the onboard SCSI channels and select a
PCI slot instead, when scanning for boot devices. For
instructions, refer to the SCSI Configuration Utility in Chapter
10, "Configuring the HP NetServer."