Lexmark W820 Service Manual - Page 119
Solenoid Assembly-Gate In Removal
UPC - 734646210508
View all Lexmark W820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
4025-Finisher Solenoid Assembly-Gate In Removal Removal 1. Remove the Rear Cover. 2. Unplug the connector (P/J 256M) of the Solenoid Assembly. 3. Unclamp the harness of the Solenoid Assembly at five places on the Bracket Assembly. 4. Pull the Roller off the shaft of the Bracket Assembly. 5. Remove two screws that secure the Cover Assembly Solenoid, and remove the Cover Assembly Solenoid together with the Solenoid Assembly-Gate In. 6. Pull the Bracket Assembly Damper off the Cover Assembly Solenoid with your fingers. 7. Remove the screw that secures Solenoid Assembly to the Cover Assembly Solenoid, and remove the Solenoid Assembly-Gate In. 8. Pull off the Link Assembly Damper together with the plunger of the Solenoid Assembly. 9. Sliding the Link Assembly Damper, remove it from the plunger of the Solenoid Assembly. Removal and Replacement Procedures 4-11