HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 136
Event, Number, DEC/hex, Event Name, Logged, Predictive, Maintenance, Implication, Suspected
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Table 14. Controller Log Event Code Descriptions Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 0/0x00 No Sense N NA None No sense data available. See the SCSI Command Specification for more information. 1/0x01 Event Log Full N NA None The controller event log is full. The log can be cleared using the SCSI Access Log command. 2/0x02 Controller Log Full N NA None The controller log is full. The log can be cleared using the SCSI Access Log command. 3/0x03 Parameter List Length Error N NA None A SCSI parameter list length error occurred. See the SCSI Command Specification for more information. 4/0x04 Invalid Field In Parameter List N NA None A SCSI invalid field in parameter list error occurred. See the SCSI Command Specification for more information. 5/0x05 No Physical Device Present N NA None A command tried to address a disk drive that doesn't exist. Check the physical configuration of the disk array to see what disk drives are installed. 136