HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 139

Recovered With, Not Enough

Page 139 highlights

Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 18/0x12 Not Enough Space Y Ignore None A write command had to move data in order to find enough space to complete. Errors were encountered during this process which prevented the controller from providing enough space for the write. This would typically result from multiple failing or missing drives. If disk drives have been removed, reinstall them in the array. 19/0x13 Command Illegal In Current State N NA None The requested operation is not allowed due to the current state of the disk array. Certain operations require the disk array to be in a specific state for execution. For example, the disk array must be shutdown to perform a download. 20/0x14 Becoming Ready N NA None The disk array has not finished its initialization. 21/0x15 Recovered With Low Level Retries Y Ignore Disk Drive Controller Internal SCSI Bus After failing the initial I/O, data was recovered using retries. It was necessary to use redundancy to recover the data. 139

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

Troubleshooting
Event Code Descriptions
139
Troubleshooting
Event
Number
(DEC/hex)
Event Name
Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
18/0x12
Not Enough
Space
Y
Ignore
None
A write command had to
move data in order to find
enough space to complete.
Errors were encountered
during this process which
prevented the controller from
providing enough space for
the write.
This would typically result
from multiple failing or
missing drives. If disk drives
have been removed, reinstall
them in the array.
19/0x13
Command
Illegal In
Current State
N
NA
None
The requested operation is not
allowed
due to the current
state of the disk array. Certain
operations require the disk
array to be in a specific state
for execution. For example,
the disk array must be
shutdown to perform a
download.
20/0x14
Becoming
Ready
N
NA
None
The disk array has not finished
its initialization.
21/0x15
Recovered With
Low Level
Retries
Y
Ignore
Disk Drive
Controller
Internal SCSI
Bus
After failing the initial I/O,
data was recovered using
retries.
It was necessary to
use redundancy to recover the
data.