HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 139
Recovered With, Not Enough
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 18/0x12 Not Enough Space Y Ignore None A write command had to move data in order to find enough space to complete. Errors were encountered during this process which prevented the controller from providing enough space for the write. This would typically result from multiple failing or missing drives. If disk drives have been removed, reinstall them in the array. 19/0x13 Command Illegal In Current State N NA None The requested operation is not allowed due to the current state of the disk array. Certain operations require the disk array to be in a specific state for execution. For example, the disk array must be shutdown to perform a download. 20/0x14 Becoming Ready N NA None The disk array has not finished its initialization. 21/0x15 Recovered With Low Level Retries Y Ignore Disk Drive Controller Internal SCSI Bus After failing the initial I/O, data was recovered using retries. It was necessary to use redundancy to recover the data. 139