Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 178/0xb2 Data Unavailable Y Ignore - See None accompanying errors The data unavailable condition was triggered. This is caused by multiple failed, downed, or missing disk drives. The condition persists as a warning until fewer than 2 drives are down, failed, or missing. If this condition occurred as a result of removing disk drives, reinstall them to correct the problem. This event also occurs if data and redundancy have been lost for any part of the disk set. The disk array must be reformatted in this case. 179/0xb3 Insufficient Optimal Space For Rebuild Y Ignore - See None accompanying errors There is insufficient disk space for rebuild to execute. This event is most likely to occur when using disk drives of different capacities. To create the necessary disk capacity, add another disk (equal in capacity to the largest disk in the array) or delete a LUN. 180/0xb4 Rebuild Restarted Y Ignore None A rebuild has been automatically restarted due to a disk failure or a disk removal. 171