Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 208/0xd0 Internal SCSI Bus State Event Y Single Controller A disk drive responded Occurrence Disk Drive incorrectly. The result was an Internal SCSI internal SCSI bus reset, and a Bus hot-plug recovery sequence to regenerate the bus state. The control panel display may indicate "verifying drives" as a result of the internal bus reset. 209/0xd1 Uncorrectable ECC Error During Initialization Y More than 1 SIMM in 6 months if Controller no operator activity The controller experienced an unrecoverable error during power on. This is expected in any of the following situations: - The batteries have been fully discharged. - The batteries were disconnected from the memory - New SIMM memory was added All other situations, this event represents a true memory error. 178