HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 187
HP Surestore Disk Array FC60 Manual
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 187 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 228/0xe4 Local Controller Y Ignore if DRAM SIMM, This error code indicates that Failed DRAM recovered by Controller the DRAM SIMM on the local Address Decode reset or power controller failed the DRAM Test on address decode test during the power-on process. Specifically, the DRAM SIMM on the primary controller failed the decode test. 229/0xe5 Remote Y Ignore if DRAM SIMM, This error code indicates that Controller recovered by Controller the DRAM SIMM on the Failed DRAM reset or power remote controller failed the Address Decode on DRAM address decode test Test during the power-on process. Specifically, the DRAM SIMM on the secondary controller failed the decode test. 230/0xe6 Controller Failed Background ROM checksum test Y Ignore if ROM, recovered by Controller reset or power on This error code indicates that the ROM on the local controller failed the ROM checksum test done in the background during idle time. The firmware stored in the ROM is corrupted. 231/0xe7 Scrub policy detected error Y Ignore - should Disk drive be preceded by Drive errors This error code indicates that an error was returned to the Scrub policy by a device read. It is logged to provide information about the cause of the error. Additional information about the error from the device should precede this entry. 187