Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 170/0xaa Internal SCSI Reassign Completed Y See disk drive Disk Drive vendor's reassign rate spec. The controller successfully completed a sparing operation. The reported FRU is the slot number. 171/0xab Internal SCSI Y Ignore None Reassign Canceled A sparing operation was canceled, typically due to a hog plug event on the bus. The sparing operation will not be retried until another the bad block is accessed again. The reported FRU is the slot number. 172/0xac No Error On Disk Media After Medium Error Y Ignore unless Disk Drive medium error recurs The controller has determined that media for which a disk drive had reported a MEDIUM ERROR is actually OK. The data stored at the affected block may or may not have been recovered. The reported FRU is the slot number. 173/0xad Incompatible RAM Image Revision Y Ignore - None Operator Error The NVRAM image stored on the disk set when it was shutdown is not compatible with the current version of controller firmware. This is typically caused when upgrading controller firmware. Returning to the previous firmware revision will correct this problem without data loss. 169

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

Troubleshooting
Event Code Descriptions
169
Troubleshooting
Event
Number
(DEC/hex)
Event Name
Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
170/0xaa
Internal SCSI
Reassign
Completed
Y
See disk drive
vendor’s
reassign rate
spec.
Disk Drive
The controller successfully
completed a sparing operation.
The reported FRU is the slot
number.
171/0xab
Internal SCSI
Reassign
Canceled
Y
Ignore
None
A sparing operation was
canceled, typically due to a
hog plug event on the bus. The
sparing operation will not be
retried until another the bad
block is accessed again. The
reported FRU is the slot
number.
172/0xac
No Error On
Disk Media
After Medium
Error
Y
Ignore unless
medium error
recurs
Disk Drive
The controller has determined
that media for which a disk
drive had reported a
MEDIUM ERROR is actually
OK. The data stored at the
affected block may or may not
have been recovered. The
reported FRU is the slot
number.
173/0xad
Incompatible
RAM Image
Revision
Y
Ignore -
Operator Error
None
The NVRAM image stored on
the disk set when it was
shutdown is not compatible
with the current version of
controller firmware. This is
typically caused when
upgrading controller firmware.
Returning to the previous
firmware revision will correct
this problem without data loss.