HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 214
Altitude Ranges, Vibration, Shock, Line Input Requirements, Specs
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 214 highlights
Specs Appendix A. Product Specifications Environmental Requirements Altitude Ranges • Operating: 0 to 3,048 m (0 to 10,000 ft) • Nonoperating: 0 to 4,572 m (0 to 15,000 ft) Vibration • Operating Random Vibration: 0.21 Grms, 5 to 500 Hz • Nonoperating Random Vibration: 2.09 Grms, 5 to 500 Hz • Nonoperating Vibration Sine Sweep: 0.5 G (0 to peak), 5 to 500 Hz Shock • Operating Shock: 6.35 mm (0.25 in.) tilt drop (independent of weight) Line Input Requirements • Nominal Voltages: 100-127 Vac, 200-240 Vac • Maximum Input Power: 870 VA (7.3 A @ 120 Vac, 3.8 A @ 230 Vac) • Voltage Range: 88 - 140 Vac, 180 - 269 Vac • Nominal Frequencies: 60 Hz (120 Vac), 50 Hz (230 Vac) • Inclusive Frequency Range: 47 to 66 Hz • Transparent Line Surge: 293 Vac for 0.5 seconds • Recoverable Line Surge: 298 Vac for 0.5 seconds • Line voltage sag: 80.5 Vac for 0.5 seconds • Power Line Dropout: Must not exceed 20 ms 214