HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 156
HP Surestore Disk Array FC60 Manual
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 96/0x60 Read Recovered With RAID 5 Retries Y Ignore - See None accompanyin g errors Retries were used by the R5 module in the successful completion of a read. 97/0x61 Write Recovered With RAID 5 Retries Y Ignore - See None accompanyin g errors Retries were used by the R5 module in the successful completion of a write. 98/0x62 Read Recovered With RAID 5 Redundancy Y Ignore - See None accompanyin g errors Redundancy was used by the R5 module in the successful completion of a read. 99/0x63 Write Recovered With RAID 5 Redundancy Y Ignore - See None accompanyin g errors Redundancy was used by the R5 module in the successful completion of a write. 100/0x64 Read Recovered With RAID 1 Redundancy Y Ignore - See None accompanyin g errors Redundancy was used by the R1 module in the successful completion of a read. 101/0x65 Write Recovered With RAID 1 Redundancy Y Ignore - See None accompanyin g errors Redundancy was used by the R1 module in the successful completion of a write. 156