HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 172
At Power On, Drive Removed
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 172 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 183/0xb7 Cancel Rebuild Started Y Ignore - None Operator or Host activity A rebuild has been canceled either automatically or by command. The disk array automatically cancels a rebuild if it needs to restart rebuild due to a disk addition, a LUN deletion, or a LUN format. 184/0xb8 Rebuild IO Priority Changed Y Ignore - Host None activity The host has changed the rebuild priority. 185/0xb9 Non-Member Drive Removed Y Ignore - Operator activity None The controller detected that a disk drive was removed. This event occurs for drives that are not disk set members when they are removed. The device number field is not used. 186/0xba Drive Missing At Power On Y Ignore unless Disk Drive Indicates that a disk drive was no Operator Controller discovered to be missing activity Internal SCSI during a power on or reset. Bus This event occurs for disk set members only. The disk drive ID number assigned to the missing drive appears in the component identifier field of this log entry. A disk drive ID number consisting of the controller serial number followed by a 0 indicates that the disk drive ID number has not yet been assigned. 172