HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 144
Add Physical Drive command, During Add
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 144 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 42/0x2a Pass Through Reset Failed Y Ignore None A command to the disk drive failed. Drive status should be returned and can be examined to determine the condition of the disk drive. 43/0x2b Recovered With RAID 1 Redundancy Y Ignore - See None Accompanying Errors Redundancy was used by the controller in the successful completion of a read or write. 44/0x2c Unavailable Data Detected By RAID 1 Y Ignore - See None accompanying errors The controller detected that the disk drives necessary for a read or write were not available for access before the access was attempted. This can apply to an initial attempt to read or write, or to a retry. 45/0x2d Shutdown Failed N NA None The controller could not shutdown the disk array because all the disk drives were missing. Reinstall the missing disks to shutdown the array. 47/0x2f Disk Drive Removed During Add Physical Drive N NA None A disk drive was removed from the disk array while an Add Physical Drive command was in progress against the drive. 144