Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 187/0xbb RAM Image Upload Failed Y Single Disk Drives The controller was unable to Occurrence Controller upload a usable disk copy of Internal SCSI NVRAM during startup. This Bus may be a result of missing or failing disk drives. 188/0xbc Old Cache Configuration Used Y Ignore - See None errors associated with shutdown Write data found in the uploaded NVRAM image blocked a requested transition to a new cache configuration. The previous configuration is being used. 189/0xbd Incompatible RAM Image Content Y Ignore - None Operator error The current RAM configuration is not compatible with the RAM configuration of the NVRAM disk image. This is caused by a different mapping of NVRAM in the disk image that cannot be supported by the current configuration. For example, the disk image may support 8 GB disk drives but the current configuration does not. To use the existing disk image, the current controller map configuration must be changed to match the disk map configuration. 190/0xbe Internal SCSI Underrun Event Y Single Disk Drive A disk drive sent/received less Occurrence not Controller data than expected. accompanied Internal SCSI by other errors Bus 173