HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 138
Command Specification for, Unit Attention
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 12/0x0c Hardware Error Unit Attention N NA None Power on or self-test failure. Check system state and warning states for more information. 13/0x0d Commands Cleared Unit Attention N NA None Commands cleared by another initiator. See the SCSI Command Specification for more information. 14/0x0e Mode Parameters Changed Unit Attention N NA None Mode parameters changed by other initiator. See the SCSI Command Specification for more information. 15/0x0f Unconfigured LUN N NA None A command tried to address a LUN that hasn't been created. 16/0x10 Invalid Target LUN N NA None A command tried to perform an illegal operation on the specified LUN. For example, trying to create a LUN that already exists. 17/0x11 Invalid Source LUN N NA None A command tried to renumber a LUN that doesn't exist. 138