HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 152
Failed Start Unit, Disk Drive
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 80/0x50 Disk Drive Y Single Failed Start Unit Occurrence Command Disk Drive The disk drive returned bad status for a start unit command. The controller's retries are exhausted. 81/0x51 Unexpected Disk Drive Status Y Single Disk Drive The disk drive returned a Occurrence, Controller status inconsistent with the possible compatibility problem Internal SCSI current operation The Bus controller's retries are exhausted or the I/O is not retryable. 82/0x52 Target Storage Unchanged By Compare And Swap Y Ignore None The requested compare and swap command was valid but did not change the contents of target storage. 83/0x53 Internal Data Transfer Timeout Y Single Controller A transfer failed due to a Occurrence, Disk Drive timeout. Typically results unless with other errors Internal SCSI because the disk drive took Bus too long to complete the command. 84/0x54 Internal SCSI Bus Data Transfer Error N Single Controller A data transfer failed. This Occurrence Disk Drive error is typically accompanied unless with other errors Internal SCSI by other errors that overwrite Bus it. 85/0x55 Recovered By Disk Drive On Retry Y See drive Disk Drive vendor recommendatio n On a previous attempt(s), the disk drive failed the I/O. The controller retried the I/O and the disk drive returned a status indicating the I/O was successful. 152