HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 174
Controller ECC, Access Error
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 174 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 191/0xbf Internal SCSI Overrun Event Y Single Disk Drive A disk drive sent/received Occurrence not Controller more data than expected. accompanied Internal SCSI by other errors Bus 192/0xc0 Internal SCSI Y More than 2 Disk Drive A disk drive didn't respond Timeout Event occurrences Controller within a specified time limit. per hot plug Internal SCSI The disk drive may be failing, event Bus or it may be busy performing data retries. 193/0xc1 Controller ECC Miscorrection Y Single SIMM Occurrence Controller The system experienced a correctable error which was most likely miscorrected. 194/0xc2 Controller Data Bus Microprocessor Access Error Y Single Controller Occurrence The controller experienced a microprocessor access error without the needed other qualifiers. Microprocessor access errors should only occur in conjunction with correctable or uncorrectable memory errors, or with parity errors. If no other condition is present, this event is reported to indicate the malfunction. 174