HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 184
Troubleshooting, Event Code Descriptions
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 184 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 223/0xdf Disk Format Version Mismatch Y NA None The NVRAM format of the disks does not match the format used by the controller. This event is logged when an icicle controller attempts to use disks previously shutdown by an Ice controller or visaversa. The controller cannot use an NVRAM image in the incorrect format. 224/0xe0 Shutdown Due To Power Supply Failure Y Single Occurrence Power Supplies, Controller, Backplane This error code indicates that the Background Manager (BGM) has discovered that there are not enough good power supplies to run the system. The BGM is shutting down the subsystem to minimize system operation with inadequate power. Note: The NVRAM is posted to disk. 225/0xe1 Recovery from battery backed RAM Loss Started Y Single Controller Occurrence This error code indicates that recovery from a battery backed RAM loss has been initiated. The contents of the NVRAM that is battery backed up has been lost and the arrayrecover command has been initiated. The contents of the NVRAM has started to be rebuilt. (This is a feature only in controller firmware revisions HP54 and later.) 184