HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 45

HP SureStore E Disk Array 12H Controller, System State: Ready

Page 45 highlights

HP SureStore E Disk Array 12H Controller Firmware Download Procedure 6. Verify updated firmware revisions on both controllers using ARMServer (arraydsp -c ) or front panel. The following table shows the proper front panel commands to verify the firmware on the array: KEY CANCEL CANCEL MENU - ENTER + + + + DISPLAY "Ready" "Language" "View Settings" "System State: Ready" "Primary Cntrl: __" "SCSI ID x:__" "SCSI ID y __ "Firmware: HP__" 7. If ARMServer issues a "switch controller" command, you may have to repeat step 5 (download). NOTE! In some older versions of ARMServer, the download command had a problem recognizing the primary array controller. This happens when the primary array controller SCSI ID is a higher number than the secondary array controller SCSI ID. If this problem occurs, the download command will issue a "switch controller" command and then stop. When this happens, issuing the download command again causes the download to complete properly. 8. The disk array will display the "Ready" state when the download command has completed. Controller 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

HP SureStore E Disk Array 12H Controller
Firmware Download Procedure
45
Controller
6.
Verify updated firmware revisions on both controllers using ARMServer (
arraydsp -c <array-
id>
) or front panel. The following table shows the proper front panel commands to verify the
firmware on the array:
KEY
DISPLAY
CANCEL CANCEL
“Ready”
MENU
“Language”
“View Settings”
ENTER
“System State: Ready”
+
“Primary Cntrl: __”
+
“SCSI ID x:__”
+
“SCSI ID y __
+
“Firmware: HP__”
7.
If ARMServer issues a “switch controller” command, you may have to repeat step 5 (download).
NOTE!
In some older versions of ARMServer, the download command had a problem
recognizing the primary array controller. This happens when the primary array controller SCSI ID
is a higher number than the secondary array controller SCSI ID. If this problem occurs, the
download command will issue a “switch controller” command and then stop. When this happens,
issuing the download command again causes the download to complete properly.
8.
The disk array will display the “Ready” state when the download command has completed.