Ignore - Host, Check host error reports
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 147 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 53/0x35 Host Overlapped Commands Attempted Y Ignore- Host None Protocol Incompatibilit y Commands were attempted to be overlapped from the host. This is usually an incorrect initiator connection error, and usually reflects a SCSI protocol violation on the part of the host. 54/0x36 Unsupported Host SCSI Message Y Ignore - Host None Protocol Incompatibility An illegal/unsupported SCSI message was received. This usually reflects a SCSI protocol violation on the part of the host. 55/0x37 Host SCSI Y Ignore - See None Initiator host error Detected Error report The initiator detected an error condition (usually parity). All retries have been exhausted. Check host error reports for more information. 56/0x38 Host Invalid Message Y Ignore - Host None compatibility problem An invalid SCSI message was received. This usually reflects a SCSI protocol violation on the part of the host. 57/0x39 Host Reselection Failure Y Single Host SCSI The initiator did not respond Occurrence. Bus to reselection attempts. All Ignore if occurs with timeouts Host Controller retries have been exhausted. 58/0x3a Host Data Phase Error Y Single Host SCSI The initiator timed-out in a Occurrence Bus Host data phase. Controller 147